Multichannel analyzer for parallel counting AMP-12 "Puls-1A"
- General date
- Technical characteristics
- Modifications
Multichannel analyzer for parallel counting AMP-12 "Pulse-1A" (the analyzer) is a major structural element of the automated radiation monitoring system (ARMS) of NPPs. The analyzer is designed to create a new system or upgrade existing AKRB-03, 06,08 and their analogues.
The analyzer is intended for simultaneous reception of multiple channels of pulsesignals from the detection blocks and devices of ionizing radiation in the form of a sequence of statistically distributed pulses and measuring the counting rate of pulses; the simultaneous reception of multiple channels of analog signals the DC and voltagefrom the sensor with standardized output signals and convert them to physical quantities for each measuring channel.
- The analyzer is used in measuring information systems of radiation control for normal operating conditions on NPPs.
- The analyzer is a means of measuring equipment in accordance with GOST 27452-87 and refers to the technical means of measuring information systems of radiation control for normal operating conditions on NPPs.
- АThe analyzer refers to the technical means of automation of normal operation information systems.
- To influence the NPP safety analyzer is classified as normal operation.
AMP-12 «Puls-1A» passed the tests, it has type examination certificate number UA-TR/113-0064/02-17 (23.10.2017) which was registered in the State registry of measuring technique.
Technical specifications TU U 33.2-19130157-009-203.
|
-
Range of measuring the counting rate of pulses, s-1 |
from 0,01 to 6×104 |
The frequency range of registration the input pulses, Hz
|
from 1×10-2 to 6×104 |
Pulse amplitude, V
|
from 3 to 12 |
Pulse duration, µs
|
from 0,2 to 2,5 (at least 50% of pulse amplitude) |
The polarity of the pulse
|
positive
|
The number of channels for receiving the pulse signals
|
not more 60 |
DC current, mA
|
from 0,05 to 20 |
The range of measuring DC voltage, V
|
from 0,1 to 10 |
Number of input DC voltage and current
|
not more 60 |
The instability of readings,%
|
not more 0,5 |
Time of continuous work, hours per day
|
24 |
Operation mode setup time, min
|
not more 2 |
Measurement time, s: - when measuring the counting rate of pulses; - when measuring the DC voltage |
from 1 to 10000 not more 2 |
Power consumption including the power consumed by connected to the the analyzerdetection units and devices, VA
|
not more 950 |
The analyzer has a block - modular design and comes in three versions:
- in the cabinet for wall mounting,
which houses a set of analyzer;
- in the cabinet for wall mounting,
that houses no more than two sets of analyzer;
- in the cabinet for floor mounting,
that houses no more than three sets of blocks and units of the analyzer.
|